BZZFL - 00322 STRIPPABLE PROT COATING

  • MSDS: BZZFL
  • Manufacturer: SPRAYON PRODUCTS
  • Product Name: 00322 STRIPPABLE PROT COATING
  • National Stock Number: 8010-00N001330
Product Identification

Product ID:00322 STRIPPABLE PROT COATING
MSDS Date:05/21/1987
FSC:8010
NIIN:00N001330
MSDS Number: BZZFL

Responsible Party
SPRAYON PRODUCTS
26300 FARGO AVE
BEDFORD HTS, OH 44146
US

Emergency Phone: 216-292-7400

Info Phone: 216-292-7400

Cage: 09800

Contractor
SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC.
BEDFORD HEIGHTS, OH 44146 US

Telephone: 216-292-7400 OR 216-595-8634

Cage: 09800

Ingredients

STODDARD SOLVENT;(MINERAL SPIRITS)

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: <5%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM


PROPANE, 1-CHLORO-2,3-EPOXY-; (EPICHLOROHYDRIN) (SARA

CAS: 106-89-8

RTECS: TX4900000

Fraction By Weight: 0.059%

OSHA PEL 5 PPM, S

ACGIH TLV: 2 PPM, S

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


ACETONE (SARA 313) (CERCLA)

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 20-40%

OSHA PEL 1000 PPM

ACGIH TLV: 750 PPM; 1000 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA 313)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 15%

OSHA PEL 500 PPM; Z-2

ACGIH TLV: 50 PPM, A2

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 15%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT


2-BUTANONE; (METHYL ETHYL KETONE) (SARA 313) (CERCLA)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 25%

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM; 200 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2-PENTANONE, 4-METHYL-; (METHYL ISOBUTYL KETONE) (SARA 313)

CAS: 108-10-1

RTECS: SA9275000

Fraction By Weight: 10%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM; 75 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: <5%

OSHA PEL 200 PPM; Z-2

ACGIH TLV: 50 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:IN CONFINED AREA VAPORS IN HIGH CONC
ARE ANESTHETIC. IRRIT TO SKIN & UPPER RESP SYSTEM. OVEREXP MAY
RESULT IN LIGHT-HEADEDNESS, STAGGERING GAIT, GIDDINESS & POSS NAUS.
CNTNS PETROLEUM DISTILLATES - HA RMFUL OR FATAL IF SWALLOWED.
CHRONIC: REPORTS HAVE ASSOC RPTD/PRLNGD OVEREXP TO SOLVS W/PERM
BRAIN & (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:IARC MONO, SUPP, VOL
7, PG 194, 1987: GROUP 2B. NTP 7TH ANNUAL REPORT ON CARCINS, 1994:
ANTIC(SUPDAT)
Effects of Overexposure:HLTH HAZ:NERV SYS DMG, ALSO KIDNEY & LIVER DMG.
NOTE: TOLUENE APPEARS ON NAVY LISTING OF OCCUP CHEM REPRO HAZS.
SEEK CONSULT FROM APPROP HLTH PROFESSIONALS CONCERNING LATEST HAZ
LIST INFO & SAFE HNDLG & EXPOS INFO. CHLOROCARBON MATLSHAVE PRDCED
SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE PATIENT TO FRESH AIR. EYE: FLUSH W/WATER FOR AT
LEAST 15 MINS. SKIN: WASH W/SOAP & WATER. INGEST: CALL MD IMMED. DO
NOT INDUCE VOMITING.

Fire Fighting

Flash Point Method:TOC
Flash Point:<20F,<-7C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL OR FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESS DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT. WATER MAY BE INEFFECTIVE - WATER MAY BE
USED TO KEEP FIRE EXPOSED CONTAINERS COOL.
Unusual Fire/Explosion Hazard:DO NOT SPRAY NEAR OPEN FLAME. KEEP AT
ROOM TEMP AS EXPOS TO DIRECT SUNLIGHT/OTHER HEAT MAY CAUSE
BURSTING. THERM DECOMP PRODS MAY INCL HCL & PHOSGENE.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE &
AVOID BREATHING VAPORS & REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE >120F. KEEP AT ROOM TEMP
AS EXPOS TO DIRECT SUNLIGHT OR HEAT MAY CAUSE BURSTING.
Other Precautions:KEEP AWAY FROM CHILDREN. DO NOT PUNCTURE/INCIN. DO
NOT SPRAY NEAR FIRE OR OPEN FLAME. NO SMOKING IN AREA OF USE. DO
NOT USE IN GENL VICIN OF ARC WELDING, OPEN FLAMES/HOT SURFS. HEAT
&/UV RADIA MAY CAU SE FORMATION OF HCL &/PHOSGENE.

Exposure Controls

Respiratory Protection:AVOID BREATHING OF VAPOR OR SPRAY MIST. USE
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN.
Ventilation:PROVIDE LOC EXHST VENT IN VOL & PATTERN TO KEEP TLV OF ALL
HAZ INGS BELOW ACCEPTABLE LIMS & LEL BELOW ACCEPTABLE LIMS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS.
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN: TO BE CARCINGEN. ANIMAL: LUNG, LIVER, SALIVARY,
MAMMARY GLAND(TUMORS). EFTS OF OVEREXP: HAVE A SIMILAR EFFECT IN
HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED
EXC EPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY
EXPOSED TO CHLOROCARBONS.

Chemical Properties

Boiling Pt:B.P. Text:<0F,<-18C
Vapor Density:HVR/AIR
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:90

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:DO NOT STORE ABOVE 120F.
Hazardous Decomposition Products:BY OPEN FLAME: CARBON MONOXIDE, CARBON
DIOXIDE, HYDROGEN CHLORIDE & PHOSGENE GAS.

Disposal

Waste Disposal Methods:DO NOT INCINERATE - DISPOSE IN ACCORDANCE
W/FEDERAL, STATE & LOCAL REGULATIONS REGARDING POLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.